Test Volt resume cadence with a controlled clock

This commit is contained in:
firestar5683
2026-11-25 12:40:20 -06:00
parent 9aa473fe7e
commit 5ae118400d
2 changed files with 20 additions and 14 deletions
@@ -228,19 +228,20 @@ class TestVoltStop(unittest.TestCase):
self.assertIsNone(evidence)
def test_card_resume_provider_remains_fresh_at_actual_gas_sender_cadence(self):
import time
from openpilot.starpilot.controller_extensions import ResumePlanInputs
def clock_pair():
now = time.monotonic_ns()
return now, now
now_ns = 10_000_000_000
self.enterContext(OpenpilotPrefix())
self.enterContext(patch('openpilot.starpilot.longitudinal.inputs.clock_pair_ns', side_effect=clock_pair))
self.enterContext(patch.dict('os.environ', {'SIMULATION': '0'}))
self.enterContext(patch.object(messaging, 'time', NS(monotonic=lambda: now_ns / 1e9)))
self.enterContext(patch('openpilot.starpilot.controller_extensions.time', NS(monotonic_ns=lambda: now_ns)))
self.enterContext(patch('openpilot.starpilot.longitudinal.inputs.clock_pair_ns', side_effect=lambda: (now_ns, now_ns)))
provider = ResumePlanInputs()
pm = messaging.PubMaster(['deviceState', 'carState', 'longitudinalPlan'])
drive = time.monotonic_ns() - 1_000_000_000
drive = now_ns - 1_000_000_000
healthy = []
started = time.monotonic()
#100HzcarState/20Hzplan producers coalesce into the actual25Hzgas sender consumer.
# Advance the producer and receipt clocks independently of the runner's scheduling.
# The real queues still coalesce 100 Hz carState and 20 Hz plan into the 25 Hz consumer.
for tick in range(204):
for name, cadence in (('carState', 1), ('longitudinalPlan', 5), ('deviceState', 50)):
if tick % cadence == 0:
@@ -255,10 +256,10 @@ class TestVoltStop(unittest.TestCase):
event.longitudinalPlan.shouldStop = False
pm.send(name, event)
if tick % 4 == 0:
current = provider.update(time.monotonic_ns())
current = provider.update(now_ns)
if tick >= 120:
healthy.append(current)
time.sleep(max(0., started + (tick + 1) * .01 - time.monotonic()))
now_ns += 10_000_000
self.assertTrue(all(healthy))
tracker = provider.sm.freq_tracker['carState'].recent_avg_dt
self.assertEqual(tracker.count, tracker.window_size)
@@ -267,9 +268,14 @@ class TestVoltStop(unittest.TestCase):
event.valid = True
event.longitudinalPlan.shouldStop = True
pm.send('longitudinalPlan', event)
self.assertFalse(provider.update(time.monotonic_ns()))
time.sleep(.16)
self.assertFalse(provider.update(time.monotonic_ns()))
self.assertFalse(provider.update(now_ns))
now_ns += 40_000_000
event = messaging.new_message('longitudinalPlan', valid=True)
event.longitudinalPlan.shouldStop = False
pm.send('longitudinalPlan', event)
self.assertTrue(provider.update(now_ns))
now_ns += 160_000_000
self.assertFalse(provider.update(now_ns))
def test_ascm_card_resume_uses_physical_clock_and_monotonic_plan_with_two_second_offset(self):
from opendbc.car.gm.tests.test_ascm_intercept import params as ascm_params
+1 -1
View File
@@ -1 +1 @@
{"protected_inventory_sha256": "50b081b76510af19100843a982ecad2152f67666cc0b380a9bb5501fad12ebc3", "schema_version": 1}
{"protected_inventory_sha256": "b5fcc071d954a9087b1b74f6d742ae16bfe70b8cf765404e529765bd08ae2c20", "schema_version": 1}