The inherited hardware cleanup removed TICI's SOM hwmon readings and used
Panda health voltage for every device. Dom uses the input-power sensor on
comma 3; the DOS ADC can otherwise appear as 0.3 V in peripheralState and
Comma Connect status reports.

Restore voltage/current sampling on a TICI-only background worker. Publish a
single atomic sample pair without sysfs reads in the CAN loop, retain Panda
fallback before a reading or when both readings are zero, and preserve actual
low/zero values. Comma 3x/4 continue using Panda measurements.

Test the actual publisher, HardwareComma, worker and Capnp serialization for
TICI/TIZI/MICI, including blocked sensor I/O, fallback and unchanged faults.
All three native cases and 13 existing power-monitoring tests pass; full
AArch64 build and native Params347 validation pass. Include matching native
outputs and canonical prebuilt receipt; preserve existing firmware exactly.